2*8 SC/APC ABS cassette type
Product Description
Planar lightwave circuit (PLC) splitter is a type of optical power management device that is fabricated using silica optical waveguide technology to distribute optical signals from Central Office (CO) to multiple premise locations. It has the characteristics of small size, high reliability, wide working wavelength range, and good uniformity between channels. These are widely used in PON networks to realize optical signal power splitting as a low-cost solution.
The optical network system also requires an optical signal to be coupled to the branch distribution. The fiber optic splitter is one of the most important passive devices in the optical fiber link. It is an optical fiber tandem device with many input terminals and many output terminals, especially applicable to a passive optical network (EPON, GPON, BPON, FTTX, FTTH, etc.) to connect the ODF and the terminal equipment and to achieve the branching of the optical signal.
ABS cassette-type PLC splitter for the construction of optical networks with low requirements for placement position and environment, its compact cassette-type design can easily be placed into an optical fiber distribution box, optical fiber junction box, or any kind of box that can reserve some space. It can be easily applied in FTTx construction, optical network construction, CATV networks, and more.
The ABS cassette-type PLC splitter family includes 1x2, 1x4, 1x8, 1x16, 1x32, 1x64, 1x128, 2x2, 2x4, 2x8, 2x16, 2x32, 2x64, and 2x128, which are tailored to different applications and markets. They have a compact size with wide bandwidth. All products meet ROHS, GR-1209-CORE-2001, and GR-1221-CORE-1999 standards.
Technical Parameters
Working Temperature: -40℃~80℃
1. FTTX (FTTP, FTTH, FTTN, FTTC).
2. FTTX networks.
3. Data Communication.
4. PON networks.
5. Fiber Type: G657A1,G657A2,G652D.
6. Test required: The RL of UPC is 50dB, APC is 55dB; UPC Connectors: IL add 0.2 dB, APC Connectors: IL add 0.3 dB.
7. Wide operating wavelength: from 1260nm to 1650nm.
Specifications
1×N (N>2) PLC splitter (Without connector) Optical parameters |
|||||||
Parameters |
1×2 |
1×4 |
1×8 |
1×16 |
1×32 |
1×64 |
1×128 |
Operation Wavelength (nm) |
1260-1650 |
||||||
Insertion Loss (dB) Max |
4 |
7.2 |
10.5 |
13.6 |
17.2 |
21 |
25.5 |
Return Loss (dB) Min |
55 |
55 |
55 |
55 |
55 |
55 |
55 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
|
PDL (dB) Max |
0.2 |
0.2 |
0.3 |
0.3 |
0.3 |
0.3 |
0.4 |
Directivity (dB) Min |
55 |
55 |
55 |
55 |
55 |
55 |
55 |
WDL (dB) |
0.4 |
0.4 |
0.4 |
0.5 |
0.5 |
0.5 |
0.5 |
Pigtail Length (m) |
1.2 (±0.1) or customer specified |
||||||
Fiber Type |
G657A or as customized |
||||||
Operation Temperature (℃) |
-40~85 |
||||||
Storage Temperature (℃) |
-40~85 |
||||||
Module Dimension (L×W×H) (mm) |
100×80x10 |
120×80×18 |
141×115×18 |
2×N (N>2) PLC splitter (Without connector) Optical parameters |
|||||
Parameters |
2×4 |
2×8 |
2×16 |
2×32 |
2×64 |
Operation Wavelength (nm) |
1260-1650 |
||||
Insertion Loss (dB) Max |
7.5 |
11.2 |
14.6 |
17.5 |
21.5 |
Return Loss (dB) Min |
55 |
55 |
55 |
55 |
55 |
50 |
50 |
50 |
50 |
50 |
|
PDL (dB) Max |
0.2 |
0.3 |
0.4 |
0.4 |
0.4 |
Directivity (dB) Min |
55 |
55 |
55 |
55 |
55 |
WDL (dB) |
0.4 |
0.4 |
0.5 |
0.5 |
0.5 |
Pigtail Length (m) |
1.0 (±0.1) or customer specified |
||||
Fiber Type |
SMF-28e with 0.9mm tight buffered fiber |
||||
Operation Temperature (℃) |
-40~85 |
||||
Storage Temperature (℃) |
-40~85 |
||||
Module Dimension (L×W×H) (mm) |
100×80x10 |
120×80×18 |
141×115×18 |
Notes
1. Above parameters does without connector.
2. Added connector insertion loss increase 0.2dB.
3. The RL of UPC is 50dB, the RL of APC is 55dB.
Previous: No More